DENR-EMB Distillation and Extraction Guidelines

Environmental permitting requirements for agarwood distillation, essential oil extraction, and botanical processing facilities

The establishment of an agarwood distillation and extraction facility requires an assessment by the Department of Environment and Natural Resources – Environmental Management Bureau (DENR-EMB).

The applicable environmental requirements depend on the facility’s location, production capacity, processing technology, fuel consumption, wastewater generation, air emissions, and waste classification.

1. Applicable environmental laws and regulations

Law / RegulationApplication
PD 1586Philippine Environmental Impact Statement System
DAO 2003-30Implementing Rules and Regulations of the Philippine EIS System
RA 8749Philippine Clean Air Act
RA 9275Philippine Clean Water Act
RA 9003Ecological Solid Waste Management Act
RA 6969Toxic Substances and Hazardous and Nuclear Wastes Control Act
DAO 2013-22, as amendedHazardous waste management
RA 11038Expanded National Integrated Protected Areas System, where applicable

Primary regulatory consideration: The facility must first undergo EMB environmental screening to establish whether an Environmental Compliance Certificate (ECC) or Certificate of Non-Coverage (CNC) is applicable.

2. Environmental Compliance Certificate (ECC) or Certificate of Non-Coverage (CNC)

First step: EMB environmental screening

The facility must be evaluated under the Philippine Environmental Impact Statement System (PEISS).

Under DAO 2003-30 and the applicable screening guidelines, the classification considers:

  • Nature and scale of the operation.
  • Production capacity.
  • Project location.
  • Proximity to environmentally critical areas.
  • Potential air and water pollution.
  • Waste generation.
  • Environmental risks and cumulative impacts.

The general project categories are:

CategoryClassificationEnvironmental document
AEnvironmentally Critical Project (ECP)ECC
BNon-ECP located in an Environmentally Critical Area (ECA)ECC
CEnvironmental enhancement or mitigation projectEMB determination
DNon-ECP in a Non-ECACNC, where applicable

A CNC should not be assumed solely because a facility is small or uses agricultural raw materials. EMB must determine the project’s coverage. DAO 30.doc+2

Suggested ECC/CNC application documents

  1. SEC Certificate of Incorporation.
  2. Articles of Incorporation and business registration.
  3. Project Description Report.
  4. Project location and vicinity map.
  5. Site development and facility layout.
  6. Process flow diagram.
  7. Equipment and machinery specifications.
  8. Raw material inventory and estimated production capacity.
  9. Water consumption and wastewater generation estimates.
  10. Air emission sources and pollution control measures.
  11. Solid and hazardous waste management plan.
  12. Land ownership, lease, or authorization documents.
  13. Other documents required by the applicable EMB screening category.

3. Air Pollution Control – Permit to Operate (PTO)

RA 8749 – Clean Air Act

Distillation and extraction facilities should assess all combustion and air pollution source installations.

Potential sources of air pollution

EquipmentEnvironmental concern
Biomass-fired boilerParticulate matter and combustion gases
Diesel-fired boilerCombustion emissions
Diesel generatorExhaust emissions
FurnaceCombustion pollutants
Wood dryerHeat and possible particulate emissions
Solvent extraction systemPotential VOC emissions
CO₂ extraction systemCO₂ release and occupational safety considerations

Not every machine automatically requires a PTO. EMB Memorandum Circular 2020-17 provides guidelines for determining which air pollution source installations require a PTO and which are exempt.

PTO application checklist

  • Equipment inventory and technical specifications.
  • Boiler capacity and fuel consumption.
  • Stack and exhaust specifications.
  • Air pollution control equipment design.
  • Process flow diagram.
  • Engineering report.
  • Location and equipment layout.
  • ECC or CNC, as applicable.
  • Other documents required by EMB.

Applications are processed through the EMB Online Permitting and Monitoring System (OPMS). Air Quality Management Section+1

4. Wastewater Management – Discharge Permit

RA 9275 – Clean Water Act

Distillation and extraction activities may produce wastewater requiring treatment and regulatory assessment.

Potential wastewater sources

ProcessWastewater
Raw material washingOrganic matter and suspended solids
Hydro-distillationSpent distillation water
Steam distillationCondensate and cleaning wastewater
Equipment cleaningOil, organic residues and detergents
Boiler operationBoiler blowdown
Floor washingSuspended solids and contaminants
Sanitary facilitiesDomestic wastewater

Recommended wastewater treatment system

CAPC wastewater treatment process

1. Wastewater collection

Separate process and sanitary wastewater where appropriate

2. Screening and equalization

Remove solids and regulate wastewater flow

3. Primary treatment

Settling and separation of oils, where applicable

4. Biological or other appropriate treatment

Treatment selected based on wastewater characteristics

5. Final filtration and testing

Verify compliance with applicable effluent standards

6. Authorized discharge or reuse

Subject to applicable permit and discharge conditions

Discharge Permit requirements

The EMB CALABARZON 2026 Citizen’s Charter specifies an engineering report and PCO documentation among the requirements. The application also needs information about wastewater sources, flow, treatment, and discharge arrangements. EMB CALABARZON+1

Important: If wastewater is collected and hauled off-site or completely reused without discharge, the permit applicability must be confirmed with EMB. Do not assume that a discharge permit is automatically required or automatically unnecessary.

5. Hazardous Waste Management – RA 6969

Applicable when regulated hazardous waste is generated

A distillation and extraction facility must identify, classify, store, and properly dispose of regulated hazardous waste.

Potential wasteRegulatory consideration
Used lubricating oilUsed oil classification
Spent organic solventsSolvent waste classification
Chemical residuesBased on chemical composition
Contaminated containersBased on previous contents and contamination
Laboratory chemical wasteApplicable hazardous waste classification
Contaminated filters and absorbentsBased on contamination

Required compliance activities

  1. Register as a hazardous waste generator when applicable.
  2. Obtain a Hazardous Waste Generator ID.
  3. Classify and identify waste codes.
  4. Establish a designated hazardous waste storage area.
  5. Maintain waste inventory and records.
  6. Use authorized hazardous waste transporters.
  7. Send waste to authorized Treatment, Storage and Disposal (TSD) facilities.
  8. Maintain waste manifests and disposal documentation.

The EMB CALABARZON has a specific hazardous waste generator registration procedure under its 2026 Citizen’s Charter. EMB CALABARZON+1

6. Pollution Control Officer (PCO)

A Pollution Control Officer is responsible for coordinating environmental compliance and monitoring.

Typical responsibilities include:

  • Monitoring compliance with ECC conditions.
  • Coordinating PTO and Discharge Permit compliance.
  • Managing hazardous waste records.
  • Preparing Self-Monitoring Reports (SMR).
  • Preparing Compliance Monitoring Reports (CMR).
  • Coordinating environmental inspections.
  • Maintaining environmental monitoring records.

PCO accreditation and appointment requirements must be confirmed with EMB based on the facility’s classification and applicable regulations. EMB CALABARZON+1

7. Environmental requirements by extraction technology

The following matrix is a practical screening guide, not a determination of mandatory permits.

A. Steam distillation

  • Boiler and fuel source assessment.
  • Stack emissions assessment.
  • Condensate and wastewater management.
  • Spent biomass management.
  • PTO screening and wastewater permit assessment.

B. Hydro-distillation

  • Water consumption monitoring.
  • Spent water characterization.
  • Organic residue management.
  • Wastewater treatment assessment.
  • Boiler or heating source assessment.

C. Solvent extraction

  • Solvent inventory and safety controls.
  • VOC emissions assessment.
  • Solvent recovery system.
  • Hazardous waste classification.
  • Fire and explosion prevention.

D. Supercritical CO₂ extraction

  • High-pressure equipment safety.
  • CO₂ storage and ventilation.
  • Pressure relief systems.
  • Energy consumption.
  • Waste and spent biomass management.

8. Recommended DENR-EMB application sequence for CAPC

  1. Project planning and site assessmentPrepare site development plan, zoning documents, project description, and equipment list.
  2. ECC/CNC environmental screeningSubmit project details to EMB and obtain the appropriate environmental determination.
  3. Air pollution assessmentDetermine whether boilers, generators, furnaces, and other equipment require PTO.
  4. Wastewater assessmentDetermine discharge permit applicability and wastewater treatment requirements.
  5. Hazardous waste registrationRegister as a generator if regulated hazardous waste is produced.
  6. PCO accreditationAppoint and accredit the appropriate Pollution Control Officer.
  7. Environmental compliance implementationImplement monitoring, waste management, reporting, and ECC conditions before and during operations.

9. Official DENR-EMB resources

For a facility in Cavite or elsewhere in CALABARZON:

Office / ServiceOfficial resource
ECC/CNCEMB CALABARZON
PTOPTO application guidelines
Discharge PermitDischarge Permit guidelines
Hazardous Waste IDHazardous Waste Generator registration
Citizen’s Charter2026 EMB Citizen’s Charter
Online permittingEMB OPMS

10. Recommended CAPC Environmental Compliance Checklist

This is the proposed document package for Crown Agarwood Processing Corp.

CAPC compliance preparation

0/12 completedProject Description ReportSite Development Plan and Vicinity MapProcess Flow DiagramEquipment and Machinery InventoryECC/CNC Environmental ScreeningAir Pollution Source InventoryPTO Applicability AssessmentWastewater Characterization and Treatment PlanDischarge Permit Applicability AssessmentHazardous Waste Management PlanPCO Appointment and AccreditationEnvironmental Monitoring and Reporting Plan

11. Information needed to determine the exact CAPC permits

The most important distinction is whether the facility is purely a botanical extraction plant or also operates a conventional wood processing line.

For a more accurate DENR regulatory assessment, I recommend starting with these operating specifications:

CAPC facility assessment

1. Extraction technologySteam and hydro-distillationSupercritical CO₂ extractionSolvent extractionIntegrated extraction technologies

2. Estimated processing capacityBelow 100 kg per batch100–500 kg per batch500–1,000 kg per batchAbove 1,000 kg per batch

3. Heating or energy sourceLPGDieselBiomassElectricityCombination

4. Will the facility also process wood?YesNo – extraction onlyPrepare CAPC DENR-EMB permit assessment

The objective is to establish a compliant, integrated agarwood extraction facility without overlooking environmental permits or applying for unnecessary clearances.